| Insitu Oxygen Sensor Specification |
| Technology |
Zirconia |
| Range |
0–100% O2 Programmable |
| Accuracy |
±0.5% of FS |
| Resolution |
0.01% |
| Repeatability |
±0.5% of FS |
| Response Time |
T90 < 3 sec |
| Process Gas Temperature |
0-150° C, 0-700° C, 0-900°C, 0-1600° C |
| Probe MOC |
Stainless Steel, Inconel, Alumina |
| Diffusion Element |
Unbreakable Ceramic. Sintered Steel filter optional on request |
| O2 Probe Length |
250 mm, 500 mm, 750 mm, 1000 mm, 1500 mm, 2000 mm |
| Flange |
ANSI Cl. 150 3RF. Other Flanges on request |
| Reference Air |
Clean & Dry Instrument quality air (2 LPM) |
| Area Classification |
Safe Area. (Explosion Proof on request.) |