Tribo Dust Monitor is a single-point/basic functionality particulate monitor employing charge induction sensing for reliable continuous monitoring of particulate in stacks, ducts, and pipes.
Applications include filter leak detection, cyclone overflow, and powder flow/no flow.
As particles flow near or around the electrically isolated sensing probe, minute charge is continuously induced into the probe. The charge flows through a measurement circuit to ground. The induced charge signal is digitally analyzed and processed to provide an output.
| Measuring Range | 0-1000 mg/m³ |
| Units of measurement | mg/m3, mg/Nm3 |
| Accuracy | ±2% FSD |
| Resolution | 1mg/m³ display resolution |
| Stack Temperature | -20° to +121°C |
| Material of construction | SS 316 |
| Probe Insertion length | 305, 457, 609, 762, 914 mm |
| Positioning | 90 degree to duct wall |
| Power Supply | 24 VDC |
| Output | 4 – 20 mA Analog output |
| Digital Communication | RS 485, Modbus |
| Mounting | Wall |
| Electronic Unit Enclosure Rating | IP 65 |
| Cable Type | 3 core Interconnection Cable |
| Ambient Temperature | -20 to 50° C |
| Operating Humidity | 5 – 95% |